Difference between revisions of "CO2 Soil Respiration Chamber"
From Hackteria Wiki
(→Nondispersive infrared sensor) |
|||
Line 18: | Line 18: | ||
* https://www.mikrocontroller.net/topic/386920 | * https://www.mikrocontroller.net/topic/386920 | ||
+ | |||
+ | '''More on ABC, Automatic Baseline Correction''' | ||
+ | |||
+ | * https://www.co2meter.com/blogs/news/9290675-automatic-background-calibration-abc-in-senseair-co2-sensors-explained | ||
Immerhin kann man den Sensor per Hd-Pin (7s gegen GND) auf 400ppm (Außenluft) eichen. | Immerhin kann man den Sensor per Hd-Pin (7s gegen GND) auf 400ppm (Außenluft) eichen. | ||
− | |||
=== CCS811 === | === CCS811 === |
Revision as of 09:32, 12 April 2018
More about CO2 sensors:
Nondispersive infrared sensor
MH-Z16:
MH-Z19:
This page is about the MH-Z19 CO2 sensor and some experiments done with it:
Using the MH-Z19 CO2 sensor PWM readout, simple arduino code:
More on ABC, Automatic Baseline Correction
Immerhin kann man den Sensor per Hd-Pin (7s gegen GND) auf 400ppm (Außenluft) eichen.
CCS811
CCS BME combo
This one I ordered 2.... but check I2C adress. and connect "WAK" to GND
- #define CCS811_ADDR 0x5A //Alternate I2C Address
- myBME280.settings.I2CAddress = 0x76;
https://www.tindie.com/products/onehorse/air-quality-sensors/